Completed in 2018 by the University of Debrecen, Hungary
ION-ZCM1 has a TOTAL ORAC = H-ORAC value of 1138 μM TE /100 g
Total ORAC value for ION-ZCM1 is 1025 μM TE/ml when measured at a dilution of 12.5%
Total ORAC value for ION-ZCM1 is 740 μM TE/ml when measured at a dilution of 6.25%
Total ORAC value for Vitamin E is 580 to 585 μmol TE/g at 1:1
Total ORAC value for Vitamin C is 128 to 133 μmol TE/g at 1:1
Total ORAC value for Pepper Leaf Extract is 64.47 μmol TE/g at 1:50 or approx a 2% solution
ION-ZC1 In Vitro Antimicrobial Study On 12 Hospital Acquired Pathogens Gram-Negative And Gram-Positive Bacterias And Fungus
Completed in 2016 by the University of Debrecen, Hungary
A non-biofilm antimicrobial assays using broth microdilution-based sensitivity method.
All fungal and bacterial strains tested with ION-ZC1 concentrations below 2.125 % v/v observed a 50% turbidity within the 24-hour testing period.
ION-ZC1 In Vitro Antimicrobial Study On MRSA
Completed in 2017 by the University of Debrecen, Hungary
A non-biofilm antimicrobial assays using broth microdilution-based sensitivity method.
The results showed that MIC values for ION-ZC1 against the 10-methicillin-resistant Staphylococcus aureus isolate tested were in the range of 0.212 – 0.85% (v/v).
The Control for Vancomycin, MIC values were in the range of 4-16 mg/L.
ION-ZC1 In Vitro Antimicrobial Study On Biofilm
Completed in 2018 by the University of Debrecen, Hungary
An antimicrobial assays using a microtiter dish sensitivity method.
Minimum inhibitory concentrations (MICs) were determined after 24 hours at which a prominent decrease of 50% (average) of biofilm mass was observed over 36 isolates.